XCP™ Technology

Standard for Octane and Cetane Rating Units

XCP™ Technology remains the modern instrumentation of choice for octane and cetane testing. CFR continues to apply advances in design, measurement, and control to its XCP Technology platform.The XCP Digital Control Panel brings advanced functionality, increased automation, enhanced documentation capabilities and future expansion opportunities to the CFR fuel rating units. Designed with the operator in mind, the XCP panel is intuitive, easy-to-use, CE Mark compliant, and accommodates users of all skill levels. XCP Technology is standard on all octane and cetane testing units, and can be retrofitted to most existing CFR units.

XCP for CFR F1/F2 – Octane Rating Units
XCP for CFR F5 – Cetane Rating Units

Click here for XCP Sell Sheet

Intuitive and Complete Interface

XCP Technology combines a PC based touchscreen interface with intuitive and accessible menus for total instrument control. With XCP Technology, operators can quickly become proficient and comfortable using both Octane and Cetane testing units. Built-in prompts, automated calculations, and data logging greatly reduce the chance for operator errors, and allow operators to be quickly cross-trained for improved work flow resulting in increased throughput and productivity.

XCP Octane Rating Screen

More Consistent Results

XCP Technology provides an easy-to-learn common software interface that drives consistency in results from operator to operator. Additionally, the XCP provides test procedure guidance and handles data recording of all critical measurements. This allows a user to focus on successful unit operation and compliance to test methods. Consistency if further improved with the XCP precisely managing air and mixture temperatures, as well as and barometer influence for octane rating tests. At the end of each test, results are presented in a convenient summary and the user remains in control of next actions.

On-screen octane rating result

Automated Data Recording

XCP Technology captures critical test data automatically and displays information using bold graphics and easy-to-read charts. Auxiliary screens show live data trending for critical ambient and test parameters. All settings, adjustments, and performance data is time stamped and recorded into an on-board database. The XCP is capable of internet/network connectivity to support integration into a Laboratory Information Management System (LIMS).

XCP Cetane Rating Screen with Auxiliaries

Testing Accuracy and Accountability

XCP Technology provides the documented accountability users need to provide certifiable octane and cetane testing. All of the stored database information is accessible in a convenient tabulated spreadsheet. Data tables of all test conditions, graphs of fuel rating curves, and formatted test report documents are ready to support any testing certification requirements. With XCP, users can easily prove their results and the accuracy of their process.

 XCP Octane Final Report
XCP Octane Final Report

Speed and Flexibility

XCP Technology is quick to learn and offers easy-to-follow templates that guides new or additional users through the octane and cetane testing procedures. With automatic data recording and test report generation, XCP users are able to focus more conducting a successful test.  Further user conveniences like an automatic integrated barometer, “Next Fuel” button for progressing a test, and octane rating estimator tool for sample approximation help users save time and effort. With XCP Technology, laboratories can maximize their operator cross-training and effectiveness.

Octane Estimator Tool

Octane Analyzer – Automated RON/MON Testing

Building upon past learnings, the newest Octane Analyzer (OA) option from CFR Engines Inc. delivers the expanded benefits that users desire. The OA option is CE Mark compliant and can be applied to existing CFR F1/F2 units with XCP Technology and provide users an automated octane rating test. With the Octane Analyzer users can expect improved consistency amongst multiple operators and better repeatability on consecutive passes.

The Octane Analyzer upgrade option provides capability to run all four test procedures of the current ASTM® Methods D2699 (RON) and D2700 (MON). With the expanded benefit of being able to now run Procedure D (Bracketing OA), users can capitalize on faster octane rating test results and better utilization of lab resources

Click here for OA Sell Sheet

XCP Octane Analyzer Kit
XCP Octane Analyzer Kit

  • Automatically complete full 2-pass tests – setup test, fill fuel reservoirs, hit start and then wait for the report
  • Test with the broader Octane Number ranges of Procedure D: 72-103.5 MON and 72-108 RON
  • Manual fuel switching, air/fuel adjustments, and data recording are now automatic
  • Reduced test time of approximately 20 minutes for a complete and certifiable octane rating determination
  • Reduced fuel consumption, approximately 100 mL for each fuel (sample and two primaries)
CFR F1/F2 with Octane Analyzer
CFR F1/F2 with Octane Analyzer